Outdoors

Installation Notes

• Unit is normally balanced on HIGH speed with the furnace blower ON.

• Weatherhood arrangement is for drawing purposes only. Six feet (2m) minimum separation

is recommended. The Weatherhood must also be 18" (460mm) above grade minimum.

• The airflow must be confirmed on site using the balancing procedures found in this manual.

Dampers for
balancing
airflows

Stale air from various

parts of home.

i.e. bathrooms (if required)

Kitchens (if required)

Fresh air to house -

main living areas.

bedrooms, livingroom,

rec. room, etc.

Fully Dedicated Installation Diagrams

Fully Dedicated System

This is a stand alone HRV/ERV system which

is not connected to a force air system. Stale air

is drawn from key areas of the home (bathroom,

kitchen) while fresh air is supplied to main

living areas.
Key Points
• The HRV/ERV must be balanced.
• The duct configuration may change

depending on the HRV/ERV model. See

specifications for your unit.

• Check local codes / authority having

jurisdiction for acceptance.