Field Controls Heat Recovery Ventilator FC95HRV. User Manual

Page 22

Advertising
background image

22

Installation of the Healthy Home System™ Control (HHSC)

Choose a Location
The HHSC controller can be installed anywhere in your

home. To simplify the installation, locate the HHSC control

near the HVAC system and/or the HRV/ERV, since the

HHSC does not require routine adjustment or occupant

interaction.

To provide the occupants with direct access to the functions

of the controls, install optional accessory controls

throughout the house.

How To Install the Controller
1. Separate the HHSC controller cover from the wall plate

(mounting base) to expose mounting holes

(see illustration).

2. Route wires through large hole in the mounting base.

Mount base against wall and mark wall through

3 mounting holes.

3. If mounting on a metal or wood surface, drill three 1/8-in.

pilot holes in wall where marked for the supplied

mounting screws. If mounting on drywall or other

surface, drill appropriate holes for wall anchors or other

means of attachment.

4. Secure mounting base to wall with either the 3 screws

provided or other fasteners, while ensuring that all wires

extend through the hole in mounting base.

5. Adjust length and routing of each wire to reach the

proper terminal and connector block on mounting base,

while leaving a 1/4 in. length of extra wire. Strip only

1/4 in. of insulation from each wire to prevent adjacent

wires from shorting together when connected.

6. Connect wires to their respective terminals on the

connector block. (Figure 1) Both (R) and (C) must be

connected for proper operation. Improper wiring or

installation may damage the controller. Ensure wiring is

correct before proceeding with installation or turning the

unit on.

7. Push any excess wire into wall and against mounting

base.

8. Snap cover onto base, while ensuring pins align with

sockets in connector.

9. Once powered the HHSC automatically enters into

operating mode.

Complete the Wiring Connections
1. Refer to subsequent wiring diagrams in this manual

that correspond to the desired control configuration.

NOTE: Disregard any wiring schematic(s) included with the

HHSC Control Installation Instructions that do not pertain to

HRV/ERV control. The HHSC is also typically used to

control an FAD fresh air damper.

2. Complete all wiring connections before restoring power

to the HVAC system and HRV/ERV.

Programming the HHSC Control
1. Balance the fresh and stale airflows as instructed in this

manual.

2. Determine the cfm flow rate as instructed in this manual.

3. To obtain the desired rate of fresh air exchange, refer to

the HHSC Control Installation Instructions to determine

the On/Off timer settings for the HHSC Control. Use the

cfm flow rate determined in step 2 as the computed or

measured fresh air flow rate (as calculated in the HHSC

instructions). To ensure adequate ventilation, ensure that

the “Fan On” time is equal to or greater than the “Vent

On” time, as programmed in the HHSC Control.

4. For continuous operation of the HRV/ERV, set

“Fan On” and “Vent On” to “Un” (unlimited), and “Fan

Off” and “Vent Off” to any setting except “Un”. This

setting also causes the HVAC fan to run continuously.

NOTE: The HHSC Control is factory programmed with the

default settings of the two On/Off timer values. No

configuration is required to use these factory default

settings.

Default settings:

FAN OFF

20 minutes

FAN ON

10 minutes

VENT ON

10 minutes

VENT OFF

20 minutes

Illustration of HHSC Control with cover off

Advertising