Round port bent to oval – Field Controls Heat Recovery Ventilator FC95HRV. User Manual

Page 9

Advertising
background image

Port Configuration and Airflow

Model FC95HRV

In order to make the HRV as space efficient as possible, the

INDOOR supply and return ports are converted from round to oval

shape. Overall size of the port remains the same. Simply bend a

standard duct fitting to the correct shape, and attach to the oval

port using the same method as for a round port.

FC95HRV Air Flow

Stale air enters the FRONT-RIGHT side port. The air passes down

the front half of the core, then up the back half of the core and out

the RIGHT-REAR port.

Fresh outdoor air enters the LEFT-REAR port and passes down

the back half of the core. Then the fresh outdoor air passes up the

front half of the core and out the LEFT-FRONT port. This

configuration allows the air to actually travel through the core

twice, which makes the FC95HRV nearly as efficient as a double

core unit.

Round port bent to oval