The Dehumidistat Ventilation Control offers ON/OFF, High

Speed/Low speed plus an electronic dehumidistat.

Key Features

• 2 Speed Fan setting (Low/High)
• Electronic Dehumidistat
• Instruction Card is inserted in the control
• Slim-line design
• Connect to 3 wire 20 gauge low voltage wire.

Turning on the Control

Press and release the ON/OFF button. The "ON Indicator Light"

will illuminate.

Adjusting the Ventilation Speed

The unit will normally operate at low speed. Press and release the

SPEED button to initiate high speed ventilation. The "High Speed

Indicator LED" will illuminate.

Humidity Control

Your unit will produce a dehumidifying effect when outdoor

humidity levels are lower than indoor humidity levels. Never use

the dehumidistat feature when outdoor temperatures are above

59° F (15° C).

Setting the Dehumidistat

Press and release the DEHUMIDISTAT button until the

DEHUMIDISTAT LED is at the desired setting. After 5 seconds

the dehumidistat light will either flash or be on continuous.
A flashing light indicates the humidity level is higher than the

setting and the unit is operating on high speed ventilation. A

continuous light indicates the humidity level is lower than the

setting.

5

The Dehumidistat Ventilation Control Part #DHVC

Instruction card

Dehumidistat

Indicator LEDs

ON/OFF

button

High/Low

Speed

button

High Speed

Indicator LED

On

indicator

light

*Install a jumper between 2 (ON) and 3 (RED) on the
HRV/ERV terminal block to configure the ON/OFF
button to ON/STANDBY. Refer to “Setting Standby
when using a Main Control” in this manual.