Frymaster 8196428 User Manual

Page 10

Advertising
background image

1-6

8. Reconnect the element connector ensuring that the latches lock.

9. Insert the temperature probe leads into the 12-pin wiring harness connector C-6 (see illustration

below). For full-vat, the red lead goes into position 3 and the white into position 4.

10. Reconnect the 12-pin connector C-6 of the wiring harness disconnected in Step 2.

11. Lower the element down onto the basket rack.

12. Reinstall the tilt housing and back panels, reposition the fryer under the exhaust hood, and

reconnect it to the electrical power supply.



1.7 Replacing Contactor Box Components

1. Remove the filter pan and lid from the unit.

2. Disconnect the fryer from the electrical power supply.

3. Remove lower back of fryer.

4. Remove the two screws in the element wire bracket (white arrow) and the six screws on the

contactor box (black arrows). Remove the back of the contactor box, leaving the lid and box
in place.


Remove the two screws in the element bracket (white arrow) and six screws on the
contactor box (black arrows) before attempting to remove the box.

Advertising