3. Remove the two screws from the upper corners of the control panel and allow the control panel

to swing down.


4. Unplug the wiring harness from the 15-pin connector on the interface board and disconnect the

grounding wire from terminal adjacent to the 15-pin connector on the back of the controller.
Remove the control panel assembly by lifting it from the hinge slots in the control panel frame.


5. Disconnect the wiring from the component to be replaced, being sure to make a note of where

each wire was connected.


6. Dismount the component to be replaced and install the new component, being sure that any

required spacers, insulation, washers, etc. are in place.

NOTE: If more room to work is required, the control panel frame assembly may be removed by
removing the hex head screws that secure it to the fryer cabinet (see illustration below).
Removing the component box itself from the fryer is not recommended due to the difficulty
involved in disconnecting and reconnecting the oil-return valve rods, which pass through
openings in the component box.

7. Reconnect the wiring disconnected in Step 3, referring to your notes and the wiring diagrams on

the fryer door to ensure that the connections are properly made. Also, verify that no other wiring
was disconnected accidentally during the replacement process.


8. Reverse Steps 1 through 4 to complete the replacement and return the fryer to service.

1.4 Replacing a High-Limit Thermostat


1. Remove the filter pan and lid from the unit. Drain the frypot into a Shortening Disposal Unit

(SDU) or other appropriate metal container.

DANGER

DO NOT drain more than one full frypot or two split frypots into the SDU at one time.

2. Disconnect the fryer from the electrical power supply and reposition it to gain access to the rear

of the fryer.