Frymaster 8196428 User Manual

Page 17

Advertising
background image

1-13

1.10 Interface Board Diagnostic Chart

The following diagram and charts provide ten quick system checks that can be performed using only
a multimeter.















Meter Setting

Test

Pin

Pin

Results

12 VAC Power

50 VAC Scale

3 of J2

1 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

Chassis 24-30 VAC

*Probe Resistance

R X 1000 OHMS

11 of J2

10 of J2 See Chart

High-Limit Continuity

R X 1 OHMS

9 of J2

6 of J2

0 - OHMS

Latch Contactor Coil

R X 1 OHMS

8 of J2

Chassis 3-10 OHMS

Heat Contactor Coil

R X 1 OHMS

7 of J2

Chassis 11-15 OHMS

* Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.

Diagnostic LED Legend

CMP indicates power from 12V transformer
24V indicates power from 24V transformer

HI

(RH) indicates output (closed) from right latch relay

HI

(LH) indicates output (closed) from left latch relay (if

present)

HT

(RH) indicates output from right heat relay

HT

(LH) indicates output from left heat relay (if present)

AL

(RH) indicates output (open) from right latch relay

AL

(LH) indicates output (open) from left latch relay (if
present)

PN 106-6666

NOTE - When testing on J1 and/or J2, use the
illustration above. Pin 1 is located on the
bottom right corner of both J1 and J2.
Disregard any silk-screened or painted
numbers on the board showing the location
of Pin1.

Advertising