5. Raise the element and remove the securing probe bracket and metal tie wraps that secure the

probe to the element (see illustration below).


6. Gently pull on the temperature probe and grommet, pulling the wires up the rear of the fryer and

through the element tube assembly.


7. Insert the replacement temperature probe (wires first) into the tube assembly ensuring that the

grommet is in place. Secure the probe to the elements using the bracket which was removed in
Step 5 and the metal tie wraps which were included in the replacement kit.

8. Route the probe wires out of the tube assembly following the element wires down the back of the

fryer through the Heyco bushings to the 12-pin connector C-6. Secure the wires to the sheathing
with wire ties.

9. Insert the temperature probe leads into the 12-pin connector C-6 (see illustration below). For

full-vat units, the red lead goes into position 3 and the white lead into position 4 of the connector.


10. Secure any loose wires with wire ties making sure that the lead wires will not interfere with the

movement of the springs. Rotate the elements up and down making sure that movement is not
restricted and that the wires are not pinched.

11. Reinstall the tilt housing and back panels, reposition the fryer under the exhaust hood, and

reconnect it to the electrical power supply to return the fryer to service.