11 alarms, 1 audio alarm on/off – Furuno NAVNET GD-1920C User Manual

Page 136

Advertising
background image

4. VIDEO SOUNDER OPERATION

4-15

4.11 Alarms

The sounder section has five conditions which generate audio and visual alarms: bottom
alarm, fish alarm (bottom lock), fish alarm (normal) and water temperature alarm
(temperature sensor required).

You may set up the sounder alarms on the SOUNDER ALARM menu, which may be
displayed by pressing the

ALARM key.

SOUNDER
ALARM

EDIT

CLEAR
ALARM

RETURN

AUDIO ALARM INTERNAL BUZZ
BOTTOM ALARM OFF
TEMPERATURE ALARM OFF

FISH ALARM OFF
FISH ALARM (B/L) OFF

ALARM INFORMATION

NO ALARM

Sounder alarm menu

4.11.1 Audio alarm on/off

The audio alarm sounds whenever an alarm setting is violated. You can enable or disable
the audio alarm as follows:

1. Press the

ALARM key to show the ALARM menu.

2. Use the

Trackball

to select ALARM AUDIO.

3. Press the EDIT soft key to show the audio alarm window.

AUDIO ALARM

INT & EXT BUZZ
INTERNAL BUZZ
OFF

Alarm audio window

4. Use the

Trackball

to select INT & EXT BUZZ (Internal + External alarm), INTERNAL

BUZZ (Internal alarm) or OFF. External buzzer required to select “INT+EXT BUZZ.” OFF
globally turns the audio alarm on or off for all modes, including radar.

5. Press the ENTER soft key.
6. Press the

ALARM key to close the menu.