2. RADAR OPERATION

2-10

2.11 Measuring the Bearing

There are two ways to measure the bearing to a target: by the cursor, and by the EBL
(Electronic bearing Line).

2.11.1 Measuring bearing by cursor

Use the

Trackball to place the cursor at the center of the target. The bearing to the target

appears in the range and bearing box at the bottom right-hand corner on the screen.

2.11.2 Measuring bearing by EBL

1. Press the

EBL/VRM key.

2. Press the EBL1 ON (dotted line EBL) or EBL2 ON (dashed line EBL) soft key to select

the desired EBL. The selected EBL’s indication, at the bottom of the screen, is
highlighted.

3. Rotate the

ENTER knob to bisect the radar target with the EBL. Read the EBL indication

to find the bearing to the target.

EBL
VRM

EBL1
ON

VRM2
ON

359.9 ˚R

11.70

nm

+

EBL1

(Dotted line)

EBL2

(Dashed line)

EBL2 bearing

Active marker is highlighted.

EBL1 bearing

VRM1
ON

OFFSET

EBL2
ON

EBL1

330.1

°

R

VRM1

-.---nm

EBL2

234.1˚R

VRM2

-.---nm

12/

H-UP

3nm
LP

319. 9

°

M

How to measure bearing with the EBL

4. You may hide the EBL/VRM soft keys by pressing the

EBL/VRM key.

Note: The bearing to a target may be shown relative to own ship’s heading (Relative) or
True bearing (requires heading data). This may be done with “EBL REFERENCE,” which is
in the RADAR DISPLAY SETUP menu.

2.11.3 Various EBL operations

Erasing an EBL, EBL indication: Press appropriate EBL soft key, then press the CLEAR
key. The EBL is erased and its indication becomes blank.

Erasing, hiding, moving EBL/VRM data boxes: See paragraph 2.10.4.