2. RADAR OPERATION

2-28

Automatic

 acquisition area

45

°

port

45

°

starboard

2.0

 - 2.5 nm

Automatic acquisition area

2. Press the TARGET soft key.

3. Place the cursor on the target to acquire.

4. Press the ACQ soft key.

5. Press the RETURN soft key to finish.

The plot symbol changes over time as below. A vector appears about one minute after

acquisition, indicating the target’s motion trend.

At

 acquisition

1

 min. after

acquisition

3

 min. after

acquisition

01*

01*

01*

Vector

*

 = Target number shown when TARGET ID NUMBER is

      turned on in the ARP SETUP menu.

Target

 Number

ARP plot symbols

Note: In case of the acquisition by an external ARP, the acquisition circle mark appears one

minute after acquisition.

Automatic acquisition
The ARP can acquire up to ten targets

automatically by setting an automatic

acquisition area. When automatic acquisition is

selected after acquiring targets manually, only

the remaining capacity for targets may be

automatically acquired. For example, if seven

targets have been manually acquired, three

targets may be automatically acquired.

1. Press the

MENU key to show the main

menu.

2. Press the ARP SETUP soft key to show the ARP SETUP menu.

3. Operate the

Trackball to select AUTO ACQUISITION AREA.

4. Press the EDIT soft key to show the automatic acquisition area window.

AUTO ACQ. AREA

ON
OFF

Automatic acquisition area window

5. Select ON, then press the ENTER soft key.

6. Press the

MENU key to close the menu. An acquisition area of 2.0 to 2.5 miles in range

and ±45º on either side of the heading line in bearing appears.

Note: Targets being tracked in automatic acquisition are continuously tracked when

switching to manual acquisition.