Furuno FAR-2107(-BB) User Manual

Page 107

Advertising
background image

1. RADAR OPERATION

1-85

Alarm name

(visual

indication)

Visual alarm, reason

To quit alarm status

AIS ALARM (See section 4.15.)

DUAL RADAR ALARM (Non-IMO only)

EXT RADAR
STBY

External radar is in standby

Set external radar in transmit to erase
indication.

EXT RADAR
ERROR

External radar malfunction

Restore external radar to normal
condition to erase indication.

EXT RADAR
HDG SET

Problem with heading data at
external radar.

Re-set external radar's heading data
to erase indication.

OTHER ALARM

ANCHOR
WATCH

Ship has drifted more than a
threshold value.

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.

ARRIVAL

Own ship has arrived to a
waypoint.

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.

CHECK INT-SW

Interswitch malfunction

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box. Check
interswitch.

DEPTH

Depth is lower or higher than
threshold value.

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.

HEADING SET

Heading signal has been
restored.

Press the [ALARM ACK] key to erase
the message. Match the on-screen
HDG readout with the actual compass
reading, if necessary.

MEMORY CARD
FULL

Memory card is full

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.

TARGET ALARM A target has entered (or exited)

the target alarm zone. Target
flashes.

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.

WATCH WATCH

0:00

(WATCH appears and time count
freezes at 0:00).

Press the [ALARM ACK] key or click
the WATCH box with the left button.
The WATCH box is displayed in
normal video and the timer is reset.

XTE

Own ship is off course more than
threshold value.

Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.

Advertising