54 sub monitor (a, b, c and w types) – Furuno FAR-2107(-BB) User Manual

Page 127

Advertising
background image

1. RADAR OPERATION

1-105

1.54

Sub Monitor (A, B, C and W types)

The picture from a radar outside the LAN network can be shown on this radar
(processor unit+display unit+control unit).

1. Put the cursor in the ANTENNA box at the upper left side of the screen.
2. Right-click to show the ANT SELECT menu.

[ANT

SELECT]


ANT1:

X-BAND

12

FORE

ANT2:

X-BAND

12

MAIN TOP

ANT3: X-BAND

MAIN TOP

12

ANT4: X-BAND
AFT


OWN RADAR No.: 2

1 DISP1

ANT1

MASTER

2 DISP2

ANT2

MASTER

* Not available on IMO or A radar.

9 STORE INTER-SW
NO/YES
0 SUB MONITOR*
OFF/ON

3 DISP3

ANT3
MASTER

4 DISP4

ANT4
MASTER

12

3. Spin the scrollwheel to select 0 SUB MONITOR then push the left button.
4. Spin the scrollwheel to select ON then push the left button.

The antenna box shows "SUB" and the image from the sub monitor is shown
on this radar

5. Push the right button to close the menu.

Antenna-related functions of the sub monitor; for example, pulselength, cannot
be controlled from this radar.

Advertising