Furuno FAR-2107(-BB) User Manual

Page 87

Advertising
background image

1. RADAR OPERATION

1-65

[CONDITION

MENU]


1 BACK
2 SEA CONDITION

1/2/3/4/5

3 ANT HEIGHT

5/7.5/10/15/20/
25/30/35/40/45/
more50m

4 LOW LEVEL ECHO
0

3. Set items 1-6 and 8 referring to the following sections:

1 INT REJECT: 1.25

5 AUTO STC: 1.17

2 ECHO STRETCH: 1.26

6 AUTO RAIN: 1.18

3 ECHO AVERAGE: 1.27

8 PULSE: 1.15

4 NOISE REJ: 1.28

4. Select 7 VIDEO CONTRAST.
5. Select 1, 2, 3 or 4 (Dynamic Range) or A, B, C (Curve) as appropriate. Refer

to the description below and the illustration on the next page.
1-4: Control dynamic range. 1 provides the widest dynamic range; 4 is the
narrowest dynamic range.
A: Mid-level in the curve is low, so this setting is suitable for reducing rain
clutter.
B: Curve between A and C.
C: Mid-level in the curve is high, so this setting is suitable for detecting
distant targets.

5 db

7 db

9 db

11 db

4

3

2

1

C

B

A

PICTURE level

VIDEO SIGNAL level

* *

* Default

Video contrast settings

6. Select 9 [CONDITION] then push the scrollwheel to show the CONDITION

menu.









CONDITION menu

7. Select 2 SEA CONDITION.
8. Select appropriate sea condition. The larger the number the rougher the sea

state.

Advertising