Life Expectancy of Major Parts

Parts Type Life

expectancy

Remarks

Antenna Motor

D8G-516 (24 rpm, X-band)
D8G-571 (42 rpm, X-band)
RM-7398 (21/26 rpm, S-band)
RM-7435 (21/26 rpm, S-band)
RM-9519F (45 rpm, S-band)
RM-9520F (45 rpm, S-band)
RM-9521F (45 rpm, S-band)

Gear motor
10,000 h

Carbon brush

MG120-5X6X11 D8G (X-band) 2,000 h

Check for wear when
replacing magnetron.
Replace if worn.

Magnetron

MAF1565N (X-band, 12 kW)
MG5436 (X-band, 25 kW)
MG5223F (S-band, 30 kW)

4,000 h
4,000 h
7,000 h

Check no. of hours
used at Tx time. Reset
time after replacement.

Backlight Unit for
Display Unit
MU-201CR

201LHS2F

45,000 h (25°C)
30,000 h (50°C)

Replace when brilliance
is uneven or too low.

Cold Cathode
Fluorescent Lamp
for Display Unit
MU-231CR

FLCL-23

50,000 h (25°C)
35,000 h (50°C)

Replace when brilliance
is uneven or too low.

LCD assy.
(MU-170C)

856JAU1745V3 40,000

h

LCD assy.
(MU-190)

LQ190E1LX51 50,000

h

LCD assy.
(MU-231)

LQ231U1LW32 50,000

h

The life expectancy figures are typical values. Actual life depends on usage.