3-8

3.4 Gas Connections (cont.)

F. After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and

evenly.

CAUTION

Qualified personnel

MUST perform any adaptation, modification, or gas conversion,

if required. Failure to use qualified personnel will void the Dean warranty.



3.5 Adjustments/Adaptation To Different Gases

A. Proper operation of appliances requires operator to scrupulously inspect the following

adjustments in terms of gas inputs and pressures.

B. Dean gas fryers are manufactured to use the type of gas and pressure specified on the rating

plate. When changing gas, adaptation must be performed by qualified personnel.
Failure to use qualified personnel will void the Dean warranty.



3.6 Gas Inputs

A. Nominal Qn Heat Input for the Super Runner SR-52 gas fryer is:

Domestic CE

120,000 BTU/Hr.

102,300 BTU/Hr.

35.19 kW

30.0 kW

126.6 megajoules

108 megajoules

B. Inputs for different gases are as follows:

G20

Natural Gas
(Type H)

20 mbar: 2.64 m

3

/ hr.

G25

Natural Gas
(Type L)

25 mbar: 3.07 m

3

/ hr.

G31

Propane

37 mbar: 1.93 kg/ hr.

Advertising