7 gas conversion: procedures (cont.) – Frymaster Dean 52 Series User Manual

Page 19

Advertising
background image

3-10

3.7 Gas Conversion: Procedures (cont.)


When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50
mbar), the following procedures apply:

♦ Check pilot-adjustment and adjust as necessary.
♦ Other adjustments are not necessary.


Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the cross-reference in Section 3.8, Gas
Conversion Components.

Conversions can only be executed by qualified, factory-authorized personnel
.

ON Button- Pilot Gas-flow

OFF Button

Pressure flow adjustment

Thermocouple connection

Pilot flow adjustment

Vent tube connection



Pressure flow adjustment
(remove cover screw to access)

ON/PILOT/OFF

Gas-Cock Knob

Pilot gas supply connection

Regulator Vent

Pilot pressure adjustment

(remove cover screw to access)

Pressure Tap

CE Gas Valve

Domestic (non-CE) Gas Valve

Advertising