SUPER RUNNER 52 SERIES GAS FRYERS

CHAPTER 6: TROUBLESHOOTING


6.1 General


CAUTION

This appliance may have more than one power supply connection point. Disconnect

all power cords before servicing.

The problems and possible solutions covered are those most commonly encountered.

To troubleshoot, perform the test set-up at the beginning of each condition. Follow each step in
sequence.


WARNING

Inspection, testing, and repair of gas or electrical equipment should be performed by

qualified personnel.

Use

EXTREME CARE when testing Live Electrical Circuits.


6.2 Pilot Burner Malfunction

A. Pilot will not ignite; no evidence of gas at pilot burner.

1. Check that gas valve is open and gas is present at the gas valve.

2. Check pilot burner orifice for dirt or lint.

3. Remove pilot burner gas-supply line and check for contamination; blow out if necessary,

then reinstall.

B. Pilot burner ignites but will not remain lit when gas valve manual knob is released.

1. Check that thermocouple lead is properly screwed into thermocouple connection bushing

on gas valve.

2. Remove end of thermocouple lead from thermocouple connection bushing and clean with

fine sandpaper or emery cloth.

3. Pilot flame may be too high or too low. Adjust pilot flame adjustment screw so that pilot

flame extends about ¾-inch (19-mm) above the top of the pilot burner.

4. Check all connections for cleanliness and security.