3.6 Gas Inputs (cont.)

C. Adjustments for different gases are as follows:

Gases and Gas Supply
Pressure*

G20

20 mbar

G25

25 mbar

G31

37 mbar

Injector Diameter

2.71 mm

2.71 mm

1.70 mm

Burner Marking

"blue" marking

"blue" marking

"red" marking

Pilot Marking

TJ024 TJ024

TJ013

"red"

Gas pressure at the regulator
(mbar)*

8.75 mbar/3.5" WC

8.75 mbar/3.5" WC

25 mbar/10" WC

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.

* For controls and adjustments, please refer to "gas valve" illustrations on page 3-10. (Pilot Flame

Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved).

WARNING

If gas odors are detected, the gas supply

MUST be shut off at the main shut-off

valve, and the local gas company or authorized service agency contacted for

immediate service.

3.7 Gas Conversion: Procedures


See page 3-10 for gas valve illustrations and page 3-11 for gas valve, burner and orifice location
when performing the following conversions.

When converting from G20 to G25 gas, the following procedures apply:

♦ Equipment replacement is not required.
♦ Adjust orifice gas pressure by turning the gas valve "adjustment screw".
♦ After adjustment, seal the screw.

When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures
apply:

♦ Burner orifices and pilot MUST be replaced.
♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw.
♦ After adjustment, seal the screw.
♦ Affix the new label included with the conversion kit next to the existing rating plate stating

that the gas type has been converted. Remove any reference to the previously used gas from
the rating plate.