CHECKING FOR PROPER VENTING

After completing and checking electrical,

gas and vent connections, follow the lighting

instructions and allow the main burner to run

for approximately 5 minutes. Hold a lighted

match or cigarette near the top edge of fire-

place opening and play it along entire length

of opening (see Figure 12). Proper venting

should tend to draw the flame or smoke into

the appliance. Improper venting or escaping

of spillage of burned gas, is indicated when

the match flickers or goes out. Smoke from a

cigarette will also tend to disperse away from

the appliance.
If the appliance is found to be improperly

venting, shut it off and notify your installer

or a qualified service agency to inspect the

venting system.

VeNtING INstallatIoN

Continued

Check this area

along entire top

edge of fireplace

opening. Smoke

or flame should

be drawn into

appliance opening.

Figure 12 - Checking for Spillage

INstallatIoN

Figure 13 - Removing Front Refractory

Access Panel

Figure 14 - Installing WRC Remote Receiver

Fireplace

Receptacle

Remote

Control

Receiver

Extension Cord

Ignition

Module Plug

NOTICE: This appliance is

equipped with a vent safety

shutoff switch which will shut

down the appliance in the case of

a venting problem. Do not bypass

the vent safety switch. If the appli-

ance should shut down, contact a

qualified installer, service agency

or your gas supplier to have the

vent inspected before operating.

WALL SWITCH INSTALLATION

The installation of a wall switch allows you

to activate the gas control valve and turn the

fireplace on and off. The wall switch is to be

connected to the incoming 120 volt regular

household wiring that supplies electricity to

the fireplace. Refer to wiring diagram in this

manual on page 18.

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held

remote control, wall switch must be in the ON

position to be operational. The remote control

then becomes the switching mechanism for

fireplace operation.
1. Remove front refractory access panel by

lifting up and angling out of firebox open-

ing (see Figure 13).

2. The WRC model receiver does not require

a battery. Receiver can be installed by

plugging the short extension cord into

fireplace receptacle. Plug receiver unit

into extension cord. Plug ignition module

plug into receiver unit (see Figure 14).