12

3" Min.

(7.6 cm)

Side W

all

Of Appliance

GAS LINE HOOK-UP

WARNING: Gas line hookup

should be done by your gas

supplier or a qualified service

person.

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

A manual shutoff valve has been included in

the appliance’s gas supply system. You may

consider installing an extra gas shutoff valve

outside appliance’s enclosure (check with

local codes) where it can be accessed more

conveniently with a key through a wall as

shown in Figure 16.
In conformance with local codes, route a

1/2" NPT gas line to appliance through hole

in left side of firebox or sub-floor as shown

in Figure 17.

CAUTION: Do not kink flex-

ible gas line.

3. Activate remote handset battery by re-

moving insulating tab on back of handset

(see Figure 15). Battery is included pre-

installed.

4. Once the battery is activated unit is ready

to use.

5. Replace front refractory access panel.

INstallatIoN

Continued

FMI PRODUCTS, LLC recommends that a

black iron gas line be routed from the gas

source, through a sediment trap (shown in

Figure 18) and into appliance. Once con-

nected through appliance, a flexible gas line

may be used for ease of installation to gas

control valve (see Figure 19, page 13).
Before connecting black iron gas line to inside

of appliance a sediment trap must be included

outside appliance between gas line and gas

shutoff valve. It must extend down 3" beyond

center of pipe. Prepare incoming black iron

gas line with teflon tape or pipe joint com-

pound (Check with local building codes).

Figure 16 - Manual Shutoff Valve

Installation

Typical Exterior Wall Gas

Shutoff Installation

Key

Extension

Shutoff

Valve

Figure 17 - Routing Incoming Gas Line

A

1/2" NPT

Incoming Black

Iron Gas Line

7"

7"

Alternate Gas Supply
Through Sub-Floor

Incoming

1/2" Gas Line

Permitted by

Local Codes

Sediment

Trap (Not

Supplied)

Figure 18 - Sediment Trap

Figure 15 - Installing Battery into Back of

Handset

Pull to Remove

Insulation Tab

Battery Cover

12 Volt Battery

Back of

Handset

M36E(B,H),

M36EP(B,H

VM36E(B,H),

VM36EP(B,H)

M42E(B,H),

M42EP(B,H)

VM42E(B,H),

VM42EP(B,H)

A

8

5

/

8

" (21.9 cm)

10

1

/

2

" (26.7 cm)

Advertising