Robertshaw

MODE

L SP745 IGNITION CONTRO

L

STEP DOWN

TRANSFORMER

PV

GND

PV/MV

TR

MV

TH

VENT SAFETY

SHUTOFF SWITCH

MANUAL

DAMPER

SWITCH

IGN

EV2

SUPPLY

INCOMING
MAIN GAS

EV1

TO

GAS LINE

BURNER

24V AC

120V AC

120V AC

INCOMING

OR BREAKER)

(FUSE BOX

OFF

ON

(NOT SUPPLIED)

WALL SWITCH

GREEN

BLACK

WHITE

120v, 60Hz, 0.7A

ELECTRICAL RATING:

BLACK

WHITE

GREEN

OPTIONAL
REMOTE

CONTROL

Pilot Burner

Pilot Gas Line

WIrING dIaGram

serVICe hINts

When Gas Pressure Is Too Low

• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low if using

propane/LP gas

If using propane/LP gas, you may feel your

gas pressure is too low. If so, contact your

local propane/LP gas supplier.