2. INTERPRETING THE DISPLAYS

2-12

Tide for three layers/tide differential

(4) Depth setting error

1

2m

2.3 140

TIDE SPD/VECTOR kt

(3) Echo from measuring layer
is abnormal

2.3 140

TIDE DIFF kt

3) Echo from measuring layer
is abnormal

1

®

2

Tide vector, speed, graph and

course plot displays

Text and echo level displays

(4) Depth setting error

1

2m

2.3 140

TIDE SPD/VECTOR

(3) Echo from measuring layer
is abnormal

kt

2.3 140

TIDE DIFF

3) Echo from measuring layer
is abnormal

1

®

2

Tide vector, speed, graph and

course plot displays

Text and echo level displays

kt

Tide and tide differential error displays

(3) Displayed when echo for a measuring layer is not present. The readout for the offending

measuring layer is not reliable.


(4) Displayed when the depth setting for a measuring layer is improper. The readout for the

offending measuring layer is not reliable.

Improper depth setting conditions

Depth in ground tracking mode is less than 10 m.

Depth setting is more than 75% of actual depth.

Echo cannot be obtained because of air bubbles, etc.

Echo for set depth cannot be found because depth has become deeper than set
depth.