3 troubleshooting – Furuno CI-68 User Manual

Page 51

Advertising
background image

4. MAINTENANCE & TROUBLESHOOTING

4-3

4.3 Troubleshooting

Below are simple troubleshooting procedures which the user may follow to try to restore
normal operation. If normal operation cannot be restored, do not attempt to check inside
any unit. Any repair work is best left to a qualified technician.

Troubleshooting table

If…

Then…

nothing appears on the screen when the
power switch is pressed

check that the power cable is firmly connected.

The fuse may have blown. Request replacement of

the fuse.

adjust brilliance.

ship’s track is not displayed

turn on SHIP TRACK in the DISP2 menu.

bottom echo is not shown on the echo
level display

check if the setting of ECHO RANGE in the MENU 1

menu is too low.

bottom is deeper than measuring range.

check setting of GAIN in the MENU1 menu.

echo display is interrupted

suspect poor measuring conditions.

bottom is covered with sludge or the like.

marine life may be adhering to the transducer.

tide data is unstable

adjust tide average on the MENU 1 menu.

interference is present

check ground for corrosion.

check if the cables of other equipment are near the

transducer cable.


Advertising