Furuno – Furuno CI-68 User Manual

Page 70

Advertising
background image

FURUNO

CI-68

SP - 2

E7252S01A

6 I/O

DATA

6.1

Format

Current loop, NMEA 0183 ver. 1.5/2/0/3.0, IEC 61162-1 Ed. 2

IEC 61162-2, current indicator (FURUNO’s own format)

6.2

NMEA input sentences ZDA, RMC, RMA, GGA, GLL, VTG, HDT, HDM, HDG, DBT, DPT,

MTW

6.3

NMEA output sentences VBW, VDR, VHW, VTG, VLW, CUR

6.4

CIF input sentences

System time, measuring position, heading, bearing, depth, water

temperature

6.5

CIF output sentences

Tide data for 1

st

layer, tide-measured speed, depths for multi-layers

6.6

Current indicator data

Date and time data, position data, speed data, current indicator data,

reverberation level data, speed calibration data, angle calibration

data, alarm output data, other

7 POWER

SUPPLY

7.1 Transceiver unit, 100/110/115-120/200/220/220/230/240 V

AC, single phase,

monitor unit, control unit 3A (100 VAC) – 1.5A (200 VAC)

8 WATERPROOFING

8.1

Monitor

unit

IPX0

8.2 Transceiver

unit

IPX0

8.3

Control unit (panel)

IPX2

8.4

Control unit (rear)

IPX0

8.5 Junction

box

IPX4

8.6 Transducer

IPX8

9 ENVIRONMENTAL

CONDITIONS

9.1

Temperature

Transducer: -5°C to 35°C

Other units: -15°C to 55°C

9.2

Relative humidity

Less than 95% (40°C)

10 COLOR

10.1

Monitor unit Panel: N3.0, Cover: 2.5GY5/1.5

10.2 Control unit

Panel: N3-2, Cover: 2.5GY5/1.5

10.3 Transceiver

unit

2.5GY5/1.5

Advertising