4 diagnostics, 1 general test – Furuno CI-68 User Manual

Page 52

Advertising
background image

4. MAINTENANCE & TROUBLESHOOTING

4-4

4.4 Diagnostics

The current indicator is equipped with several test facilities to check it for proper operation.

4.4.1 General

test

The general test mainly checks the ROM, RAM and voltages.

1. Press the [MENU] key to open the menu.
2. Press ▲ to place the cursor on the main menu title field.
3. Press ◄ to choose MENU 1.

SHIP SPEED AVG : 15 sec

30 sec 60 sec

90 sec

TIDE AVERAGE

: 2 min

REF TIDE DIFF

: LAYER 1

LAYER 2 LAYER 3

BEARING MODE : 32 CMPS 360 TRUE

NAV MODE

: OFF

ON

BOTTOM SEARCH: NO

YES

BTM TIDE TRACK : OFF

ON

ALM/KEY BEEP

: OFF

ON

WT SPD DEPTH

: 2 m (2-400m)

RESET TRIP LOG : NO

YES

TEST

: NO GENERAL PANEL PATTERN

ECHO RANGE

: 150 m

TVG

: OFF

ON

GAIN

: 5 (1-40)

PANEL DIMMER

: 5 (0-7)

MENU ON INITIAL SETTINGS.

[

F/G]:SELECT, [J/K]: CHANGE, [MENU]: EXIT

MENU 1

MENU 2

ALARM INSTALLATION

MENU 1 menu

4. Press ▲ or ▼ to choose TEST.
5. Press ► to choose GENERAL.
6. Press any function key to start the test. The results of the test are shown on the screen

as in the figure on the next page.

Advertising