3. CUSTOMZING THE SYSTEM

3-15

S

E

NE

SE

SW

W

NW

3.0kt DIR LAYER1

F

G

KEY MAX

J KKEY MIN

STATUS
0.0kt
0

°

TIDE
MIN 1.0kt
MAX 2.0kt

QUIT
ANY FUNC KEY

DIRECTION
MIN 350

°

MAX 10

°

Tide direction
alarm setting

N

N

Tide speed
alarm setting

Starting point

Ending point

Alarm setting screen (tide)

11. Press any function key to return to the ALARM menu. “

” appears to the right of DIR

in LAYER 1. When the alarm setting is violated, the audible alarm sounds and an alarm
message appears.

12. Press the [MENU] key to close the menu.

3.5.3 Setting the trip alarm

Trip distance alarm

The trip distance alarm sounds when the vessel has traveled more than the preset distance.

1. Press the [MENU] key to open the menu.
2. Press ▲ to place the cursor on the main menu title field.
3. Press ◄ or ► to choose ALARM.
4. Press ▲ or ▼ to choose TRIP-DIST.
5. Press ► to show the trip distance setting screen.

**TRIP ALARM**

J K

KEY: SET

TRIP DIST

:

0.0 nm

ANY FUNC KEY: QUIT

Distance trip alarm setting screen

6. Press ◄ or ► to set distance.
7. Press any function key to quit and return to the ALARM menu. “

” appears to the right

of TRIP-DIST. When the vessel has traveled more than the preset distance, the audible
alarm sounds and an alarm message appears.

8. Press the [MENU] key to close the menu.

Advertising