2. DSC DISTRESS COMMUNICATION

2-4

2.2 Distress Alert Transmission with Nature of

Distress

If you want to transmit the distress alert with nature of distress specified, do as
follows:

1. Open the DISTRESS key cover and press the DISTRESS key momentarily.

The alarm sounds and the red lamp in the key blinks and after releasing the key
within four seconds the alarm stops and the red lamp goes off. The following
screen appears.

** Compose Message **

NATURE : UNDESIGNATED

POS : 12

°

34N 123

°

45E

AT : 12 : 34

SIMP TP

CALL TYPE : DISTRESS

UNDESIGNATED

Fire

Flooding

Collision

Grounding

Listing

G

2. Rotate the channel knob to choose the nature of distress. On the remote

handset, press the up or down arrow key.

UNDESIGNATED

Fire

Flooding

Collision

Grounding

Listing

F

Sinking

Disabled & Adr

Abandoning

Piracy

Man over board

G

3. Press the ENT key. The screen changes as follows.

** Compose Message **

CALL TYPE : DISTRESS

NATURE : Flooding

AT : 08 : 00

POS : 34

° 41. 1234’ N

134

° 30. 4321’ E

TELEPHONE
ACK REQ

The own ship's position and current time in UTC are displayed if your
FM-8800D/8800S is connected to a navigation equipment, for example, GPS.