Basic setup, 1 alarm setup – Furuno FM-8800D User Manual

Page 77

Advertising
background image

4-1

4. BASIC

SETUP

4.1 Alarm Setup

This section provides the procedures for setting up various alarms. The alarm
menu enables/disables internal and external alarms. Note that the
Distress/Urgency alarm cannot be disabled.

Old position alarm in manual position entry mode

This alerts the operator when manually entered position data is older by the
number of hours or minutes set.

1. Press the MENU key.

**** SETUP MENU ****

ALARM

ERASE LOG

MEMORY CHANNEL

AUTO ACK

MESSAGE FILE ENTRY

T

* SETUP MENU *

ALARM

ERASE LOG
MEMORY CH

AUTO ACK

MESSAGE FILE

T

SETUP MENU on transceiver unit SETUP MENU on remote handset

2. ALARM is selected; press the ENT key to display the ALARM menu.

**** ALARM MENU ****

POSITION OLDER 4H

EXT ALARM

* ALARM MENU *

POS. OLDER
4H

EXT ALARM

ALARM MENU on transceiver unit ALARM MENU on remote handset

3. Rotate the CH knob (or press up / down arrow key) to choose POSITION

OLDER (POS. OLDER for remote handset) from the ALARM MENU and
press the ENT key. The following setting window appears.

4H

3H
2H

0.5H

1H

4. Rotate the CH knob (or press up / down arrow key) to choose an appropriate

value and press the ENT key.

Alarm is output when position is older by the number of hours set here.

5. Press the CANCEL key twice to return to standby

display.