Environmental temperature

Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3
cm from the disk drive. At designing the system cabinet, consider following points.

Make a suitable air flow so that the DE surface temperature does not exceed 55°C.

Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect

by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.

Table 4.1

Surface temperature check point

No.

Measurement point

Criteria

1

Center of DE cover

55°C

2

Read channel LSI

90°C

3

VCM/SPM Driver

92°C

4

HDC

89°C

5

MPU

88°C

1

4

5

2

3

Figure 4.6 Surface temperature measurement points

(5)

Service clearance area

The service clearance area, or the sides which must allow access to the IDD for installation or
maintenance, is shown in Figures 4.7.