7 dismounting drives, 8 spare disk drive – FUJITSU MAM3184MC/MP User Manual

Page 96

Advertising
background image

C141-E134-01EN

5 - 22

a.

Control mode parameters

Parameter

Default value

• Queue algorithm modifier

0 (Execution

sequence of

read/write

commands is

optimized.)

• QErr:

Resume or abort remaining suspended
commands after sense pending state

0 (command is

resumed)

• DQue:

Disabling tagged command queuing

0 (enabled)

5.7

Dismounting Drives

Since dismounting the drive to check the setting terminals, change the setting, or change the drive
depends on the structure of the system cabinet, the work procedures must be determined in
consideration of the requirements specific to the system. This section describes the general
procedures and notes on dismounting the drive.

It is recommended before dismounting the drive to make sure the spindle motor completely stops
after power was turned off.

a) Remove the power cable.

b) Remove the SCSI cable.

MC Model uses a single cable for power supply and the SCSI interface.

c) When the external operator panel is mounted, remove the cable. If it is difficult to access the

connector position, the cable may be removed after step e).

d) Remove the DC ground cable.

e) Remove the four mounting screws securing the drive, then remove the drive from the system

cabinet.

f)

To store or transport the drive, keep it in an antistatic vinyl pack and provide packing (see
Section 5.1).

5.8

Spare Disk Drive

See Appendix D, “Model Names and Product Numbers,” to order a disk drive for replacement or
as a spare