C141-E134-01EN

4 - 21

Table 4.2

Recommended components for connection

Applicable

model

Name

Par number

(Size)

Manufacturer

Reference

(Figures 4.25

and 4.30)

Cable socket (closed-
end type)

DHJ-PAC68-2AN

DDK

SCSI cable
(CN1)

Signal cable

UL20528-FRX-68-
P0.635

Fujikura

S1

Cable socket housing

1-480424-0

Tyco Electronics
AMP

Contact

170148-1

Tyco Electronics
AMP

Power supply
cable (CN1)

Cable

(AWG18 to 24)

S2

Cable socket housing

A3B-12D-2C

HIROSE
ELECTRIC

Contact

A3B-2630SCC

HIROSE
ELECTRIC

External
operator
panel (CN1)

Cable

(AWG26 to 36)

S3

Cable socket housing

FCN-723J016/2M

FUJITSU
TAKAMIZAWA

Contact

FCN-723J-G/AM

FUJITSU
TAKAMIZAWA

MP

External
operator
panel (CN2)

Cable

(AWG28)

S4

MC

SCSI
connector
(CN1)

Connector

71780-003

FCI

(1)

SCSI cable

See Section 1.3, “Physical Requirements”, and Section 1.4, “Electrical Requirements”, in SCSI
Physical Interface Specifications.

(2)

Power cable

IDDs must be star-connected to the DC power supply (one to one connection) to reduce the
influence of load variations.

(3)

DC ground

The DC ground cable must always be connected to the IDD because no fasten terminal dedicated
to SG is provided with the IDD. Therefore, when SG and FG are connected in the system, it is
necessary to connect SG and FG at the power supply or to connect SG of the power supply to FG
of the system.

(4)

External operator panel (MP model only)

The external operator panel is installed only when required for the system. When connection is not
required, leave open the following pins in the external operator panel connector of the IDD : Pins
21, 22 and pins 01 through 08 in CN2 and pins A1 through A12 in CN1.