CF SERIES GAS FRYERS

CHAPTER 2: INSTALLATION INSTRUCTIONS

2-9

DANGER

This appliance was configured at the factory for a specific type of gas. Converting

from one type of gas to another requires the installation of specific gas-conversion

components.


DANGER

Switching to a different type of gas without installing the proper conversion kit may

result in fire or explosion! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY

FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be

performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.7 of this manual.

Non-CE Gas Conversion Instructions

Call Frymaster Service (1-800-551-8633) to determine the conversion kit appropriate for your
configuration and altitude. Contact your local FASC to order the kit and arrange for installation.

CE Gas Conversion Instructions

1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the

CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice or pilot.

2. Between a 2

nd

family gas (G20 or G25) and a 3

rd

family gas (G31 Propane):

a.

Change

the

orifices.

b.

Change

the

pilot.

c. Change the gas valve regulator.

d. Adjust the manifold pressure.

3. Affix the new label included with the conversion kit next to the rating plate stating that the gas

type has been converted. Remove any references to the previously gas from the existing rating
plate.

4. If the destination language changes, replace the labels. Call your local service agency of kitchen

equipment supplier for a label kit. The language of reference will be on the corner of the label.





Advertising