Frymaster CF SERIES MJCFEC User Manual

Page 33

Advertising
background image

CF SERIES GAS FRYERS

CHAPTER 4: FILTRATION INSTRUCTIONS

4-8


5. Remove the Power Shower and allow it to

drain. Ensure the drain valve is fully closed
(arrow). Turn the fryer ON and allow the oil
to reach setpoint.

NOTE: Ensure the fryer drain valve is
fully closed before turning the fryer on. If
the drain valve is not fully closed, the
controller will display an error message or
a trouble light and the fryer will not
operate.



WARNING

The filter pump is equipped with a manual reset switch in case the filter motor

overheats or an electrical fault occurs. If the thermal overload switch trips, turn off

power to the filter system and allow the pump motor to cool 20 to 45 minutes before

attempting to reset the switch.










Drain handle in the
closed position.

Advertising