CF SERIES GAS FRYERS

CHAPTER 3: OPERATING INSTRUCTIONS

3-5

5. For units equipped with a Computer Magic III.5 Computer:

• Press the Power switch

followed by the Program Mode switch

.

will

appear in the left display.

• Enter the code number (1653). The right display will read

. The

temperature is automatically set for 195°F (91°C). The fryer will attain this temperature

and remain there until the Power

switch is pressed, which cancels the boil-out mode.


6. Place the fryer into operation in accordance with Section 3.1 [all except Thermostat or Solid

State (Analog) Controller- See Step #2].


7. Simmer the solution for 1 hour [all except Thermostat or Solid State (Analog) Controller- See

Step #2].


8. After the solution simmers for 1 hour [all except Thermostat or Solid State (Analog) Controller-

See Step #2], turn the fryer off, allow the solution to cool, and then add 2 gallons (8 liters) of
cold water and stir. Drain the solution into a suitable container and clean the frypot thoroughly.


WARNING

Do not drain boil-out solution into a shortening disposal unit, a built-in filtration unit,

or a portable filter unit. These units are not intended for this purpose, and will be

damaged by the solution.


Rinse the frypot at least twice by filling the frypot with clean water and draining. Dry the frypot
thoroughly with a clean, dry towel.


DANGER

Remove all drops of water from the frypot before filling with oil or shortening.

Failure to do so will cause spattering of hot liquid when the oil is heated to cooking

temperature and may cause injury to nearby personnel.