Installation – FMI PFS US VSHRP26M User Manual

Page 13

Advertising
background image

www.fmiproducts.com

125311-01A

13

Equipment

Shutoff

Valve

Propane/LP

Supply Tank

Thermostat Gas Valve

Equipment

Shutoff

Valve

Gas

Meter

Thermostat Gas Valve

INSTALLATION

Continued

2. Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve

for propane/LP gas or opening main gas

valve located on or near gas meter for

natural gas or using compressed air.

4. Check all joints of gas supply piping system.

Apply a commercial leak detection solution

to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected

fittings for leaks.

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Fig-

ure 16).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve

for propane/LP gas or opening main gas

valve located on or near gas meter for

natural gas or using compressed air.

3. Check all joints from gas meter for natural

gas (see Figure 17)) or propane/LP supply

to equipment shutoff valve (see Figure

18). Apply a noncorrosive leak detection

fluid to all joints. Bubbles forming show a

leak.

4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS

CONNECTIONS

1. Open equipment shutoff valve (see Figure

16).

Figure 17 - Checking Gas Joints for

Natural Gas (actual heater may vary from

illustration)

Figure 18 - Checking Gas Joints for

Propane/LP Gas (actual heater may vary

from illustration)

Open

Closed

Equipment

Shutoff Valve

Figure 16 - Equipment Shutoff Valve

2. For natural gas, open main gas valve lo-

cated on or near gas meter. For propane/

LP gas, open propane/LP supply tank

valve.

3. Make sure control knob of heater is in the

OFF position.

4. Check all joints from equipment shutoff

valve to thermostat gas valve (see Figure

17 or 18). Apply a noncorrosive leak de-

tection fluid to all joints. Bubbles forming

show a leak.

5. Correct all leaks at once.
6. Light heater (see Operation page 14).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to

Appliance, page 15).

8. Replace front panel.

Advertising