10. To shut off burners only and leave pilot

lit, turn control knob clockwise

to

the PILOT position.

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 21 - Pilot

OPERATION

Continued

Thermocouple

Ignitor Electrode

Pilot Burner

LOW

OFF

Control

16,000 &

26,000 &

Knob

18,000 Btu/Hr

30,000 Btu/Hr

LOW

HI

HI

OFF

MED

MED

Control

16,000 &

26,000 &

Knob 18,000 Btu/Hr

30,000 Btu/Hr

OFF

OFF

ON

ON

THERMOSTAT MODELS

Turn thermostat control knob counterclock-

wise to the desired heating level. The main

burner should light. Set control knob to any

heat level between 1 and 5 (see Figure 23).

Figure 22 - Burner Patterns for Manual

Control Models

Figure 23 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

3. Close equipment shutoff valve (see Figure

16, page 13).

TO SELECT

HEATING LEvEL

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

MANUAL CONTROL MODELS

WARNING: When running

heater, set control knob at LOW,

MED or HI locked positions.

Never set control knob between

locked positions. Poor combus-

tion and higher levels of carbon

monoxide may result.

Slightly press in control knob and turn coun-

terclockwise to the LOW, MED or HI positions

(see Figure 22).
IMPORTANT: Release downward pressure

while turning control knob. Control knob will

lock at the desired position.