OPERATION

Continued

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these

models differs from standard thermostats.

Standard thermostats simply turn on and off

the burner. The thermostat used on this heater

senses the room temperature. At times the

room may exceed the set temperature. If so,

the burner will shut off. The burner will cycle

back on when room temperature drops below

the set temperature. The control knob can be

set to any comfort level between 1 and 5. All

plaques will turn off and on.
Note: The thermostat sensing bulb mea-

sures the temperature of air near the heater

cabinet. This may not always agree with

room temperature (depending on housing

construction, installation location, room size,

open air temperatures, etc.) Frequent use of

your heater will let you determine your own

comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 5 under Lighting

Instructions, page 14.

3. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

4. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,

release control knob. Now follow step 9

under Lighting Instructions, page 14.

5. Replace front panel.

BLOWER

OPERATION

WARNING: Blower acces-

sory must be grounded. Blower

comes with a three-prong,

grounding plug as shown in

Figure 24. The plug is your

protection against electrical

shock. Plug it into a standard,

three-hole, grounded, outlet. If

cord needs replacing, use only a

cord with a three-prong, ground-

ing plug.

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and danger-

ous operation.

CAUTION: Do not plug power

cord into electrical outlet until

installation is complete.

Extension Cord

Use extension cord if needed. The cord must

have a three-prong, grounding plug and a

three-hole receptacle. Make sure cord is in

good shape. It must be heavy enough to carry

the current needed. An undersized cord will

cause a drop in line voltage. This will result in

loss of power and overheating. Use a No. 16

AWG cord for lengths less than 50 feet.

CAUTION: Verify proper op-

eration after servicing.

Operating Blower

The blower is connected to a thermostat.

When unit heats up, the blower will operate.

A few minutes after unit cycles off or is turned

off, blower will shut off. Blower will cycle on

and off in this manner. Note: If you have a

heater with a thermostat, the heater and

blower will not turn off and on at exactly the

same time. Blower cycle times will vary with

heat setting selected.

Grounded

Outlet

Figure 24 - Grounding Plug

Thermostat

Sensor

Switch

Green

White

Green

White

110/115

V.A.C.

Blower

Motor

Black

Black

Figure 25 - Wiring Diagram for Blower