LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING: Maintain the

minimum clearances shown

in Figure 4. If you can, provide

greater clearances from floor,

ceiling and joining wall.

You can locate heater on floor, away from

a wall. An optional floor mounting stand is

needed. Purchase the floor mounting stand

from your dealer. See Accessories, page 27,

if stand is not included with your heater.

WARNING: Never install the

heater

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture, cloth-

ing or other flammable objects

are less than 36" (91.5 cm)

from the front, top or sides of

the heater

• as a fireplace insert

• in high traffic areas

• in windy or drafty areas

CAUTION: If you install the

heater in a home garage

• heater pilot and burner must

be at least 18" (45.7 cm) above

floor

• locate heater where moving

vehicle will not hit it

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning fluids,

oil or kerosene lamps, etc.) in the

air exist, may discolor walls or

cause odors.

Figure 4 - Mounting Clearances As

Viewed From Front of Heater

Figure 5 - Attaching Thermostat Sensing

Bulb

INSTALLATION

Continued

Minimum

From

Sides Of

Heater

2" (5.1 cm)

FLOOR

CEILING

36"

(91.5 cm)

Minimum

Minimum To

Top Surface

Of Carpeting,

Tile Or Other

Combustible

Material

Left

Side

Right

Side

10" (25.4 cm)

36"

(91.5 cm)

Clip

Thermostat

Sensing

Bulb

IMPORTANT: Vent-free heaters add moisture

to the air. Although this is beneficial, installing

heater in rooms without enough ventilation

air may cause mildew to form from too much

moisture. See Air for Combustion and Ventila-

tion, page 5. If high humidity is experienced,

a dehumidifier may be used to help lower the

water vapor content in the air.
For convenience and efficiency, install heater
• where there is easy access for operation,

inspection and service

• in coldest part of room
If not included with your heater, an optional fan

kit is available from your dealer. See Acces-

sories, page 27. If planning to use fan, locate

heater near an electrical outlet (see page 16).

THERMOSTAT SENSING BULB

(Thermostat Models Only)

The thermostat sensing bulb has been placed

below the heater.
1. Place clip on thermostat sensing bulb as

shown in Figure 5. Clip is provided in hard-

ware package.

2. Snap clip into upper mounting hole as shown

in Figure 5. Mounting hole is located on lower

left edge on back of heater. Make sure ther-

mostat sensing bulb is pointing up.