Operation – FMI PFS US VSHRP26M User Manual

Page 14

Advertising
background image

www.fmiproducts.com

125311-01A

14

OPERATION

in the safety information, column 1. If you

don’t smell gas, go to the next step.

6.

Thermostat Models: Turn control knob

counterclockwise

to the PILOT

position. Press in control knob for five (5)

seconds.

Manual Models: Press in and turn control

knob counterclockwise

to the PILOT

position. Keep control knob pressed in for

five (5) seconds.

7. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. Note: You may be running this

heater for the first time after hooking up to

gas supply. If so, you may need to press

in control knob for 30 seconds or more.

This will allow air to bleed from the gas

system. If needed, keep pressing ignitor

button until pilot lights. If ignitor does not

light pilot, refer to Troubleshooting, page

18 or contact a qualified service person

or gas supplier for repairs. Until repairs

are made, light pilot with match. To light

pilot with match, see Manual Lighting

Procedure, page 16.

8. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,

release control knob.

• If control knob does not pop out when

released, contact a qualified service per-

son or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4

through 7. Wait one (1) minute before

lighting pilot

9. Turn control knob counterclockwise

to desired heating level. The main burner

should light. Manual control heaters

should be used in locked positions.

Figure 20 - Control Knob in the OFF

Position for Thermostat Models

Figure 19 - Control Knob in the OFF

Position for Manual Control Models

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting

the pilot, follow these instructions

exactly.

B. BEFORE LIGHTING smell all around

the appliance area for gas. Be sure to

smell next to the floor because some

gas is heavier than air and will settle

on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, don’t

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect

the appliance and to replace any part of

the control system and any gas control

which has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information

above.

2. Make sure equipment shutoff valve is

fully open.

3. Turn off any electric power to the appli-

ance if service is to be performed.

4. Turn control knob clockwise

to the

OFF position.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the

floor. If you smell gas, STOP! Follow “B”

Control

Knob

O

OT

Control

Knob

Advertising