Icemaker cleaning & sanitizing – Follett Symphony 50HI400A 23 User Manual

Page 10

Advertising
background image

10

25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A

1. Remove the upper front cover.
2. Remove splash panel and lower drain pan protector.
3. Turn compressor switch on electrical box of

icemaker to OFF position.

4. Remove water reservoir cover and close water

supply valve.

5. Drain water from reservoir by releasing evaporator

drain line from float reservoir bracket and removing

plug from drain line.

6. Following manufacturer’s instructions, prepare one

gallon (3.8L) cleaning solution A or equivalent.

Solution temperature must be at least 120 F (49 C).

WARNING: Most ice machine cleaners contain

citric or phosphoric acid that can cause skin

irritation. Read caution label on product and follow

instructions carefully.

7. Plug drain hose, replace drain line in reservoir

bracket and pour part of cleaning solution into

reservoir, filling it almost to overflowing.

8. Remove stainless steel compression nozzle and

drain lines and submerge in a cup of cleaning

solution while cleaning rest of system.

CAUTION: To avoid potential pitting, do not soak

parts in SafeCLEAN for more than 45 minutes.

9. Restore power to icemaker (gearmotor will run;

compressor and fan will not).

10. After 15 minutes, turn power OFF;

drain solution from reservoir and evaporator.

11. Fill reservoir almost to overflowing with clean,

120 F (49 C) water, and drain. Repeat three times.

12. Following manufacturer’s instructions, prepare

1 gallon (3.8L) sanitizing solution B. Solution

temperature must be at least 120 F (49 C).

13. Rinse compression nozzle in clean water and

submerge in a cup of sanitizing solution while

following steps 14-19.

14. Connect ice transport tube directly onto evaporator

outlet port without compression nozzle.

Note: If bin will not be cleaned at this time, place a

large pan in bin storage area to catch ice or connect

a separate ice transport tube to evaporator and

divert ice into separate container.

15. Fill reservoir almost to overflowing with sanitizing

solution.

16. Restore power to icemaker (gearmotor will run;

compressor and fan will not).

17. After 10 minutes, turn compressor switch to ON

position.

18. As unit starts to make ice, continue to pour

sanitizing solution into reservoir, maintaining level

just below reservoir overflow.

19. Continue to make ice with sanitizing solution for

20 minutes.

Icemaker cleaning & sanitizing

Periodic cleaning of Follett’s icemaker system is required

to ensure peak performance and delivery of clean,

sanitary ice. The following cleaning procedures should be

performed at least as frequently as recommended, and

more often if environmental conditions dictate.

WARNING

• To reduce risk of electrical shock disconnect

power before servicing

• Wear rubber gloves and safety goggles (and/

or face shield) when handling ice machine

cleaner or sanitizer mixtures

CAUTION

• Use only Follett approved cleaners (see procedure below)
• It is a violation of Federal law to use these solutions in a

manner inconsistent with their labeling

• Read and understand all packaging instructions before use
• Do not use solvents, abrasive cleaners, metal scrapers or

sharp objects to clean any part of the dispenser

Quarterly air filter cleaning

1. Remove screw at top of louvered panel on left side

of unit.

2. Slide panel toward back of dispenser and lift.
3. Remove the air filter located under the louver.
4. Clean with soap and water.
5. Rinse, and replace when completely dry.

Semi-annual icemaker cleaning & sanitizing

Note: If icemaker and dispenser are cleaned and

sanitized at the same time, icemaker should be cleaned

and sanitized first.

Cleaning solution

Solution A: Ice machine cleaner: Prepare one gallon

(3.8L) of Follett SafeCLEAN™ Ice Machine cleaner (one

7 oz packet) or equivalent. Solution temperature must be

at least 120 F (49 C).
Warning: Most ice machine cleaners contain citric or

phosphoric acid that can cause skin irritation. Read

caution label on product and follow instructions carefully.

Sanitizing solution

Solution B: Prepare sanitizing solution (50 ppm of

available chlorine content) of Ecolab Mikro-chlor Cleaner

or equal chlorinated detergent. Solution temperature

must be 75 F – 125 F (24 C – 52 C).
Note: Before cleaning SensorSAFE units, deactivate

dispenser by depressing and releasing clean switch

located on left side of unit under top front cover. When

cleaning is complete, reactivate by depressing and

releasing clean switch a second time. Dispenser will

automatically reactivate after two minutes.