Icemaker troubleshooting – Follett Symphony 50HI400A 23 User Manual

Page 32

Advertising
background image

32

25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A

Icemaker troubleshooting

Flashing water LED at any time indicates that water signal to board had been lost for more than one second.

Ten-second delay: There is a 10 second delay in reaction to loss of water (WTR) or bin (B-E) signals. If signals are not

lost for more than 10 seconds, no reaction will occur.

Problem

Indicators

Corrective Action

Icemaker will not run.

System status: compressor,

gearmotor, and fan motor

inoperative.

1. No power to unit.
2. Open bin level control.
3. Water OK LED (WTR) not on.
4. 20M or 2ND LED is on indicating that first or

second torque error has occurred.

5. Gear motor locked up (immediate torque error

indicated by LEDs when board is reset).

6. Open coil on gearmotor start relay causing an

immediate torque error.

1. Check that unit is plugged in, circuit breakers are on.
2. Adjust or replace ice level control.
3. Check reservoir for water, restore water to unit.
4. See #6 below.

5. Repair or replace gearmotor.

6. Replace gearmotor start relay.

Compressor will not run.

System status: gearmotor

and fan motor run.

1. Condenser coil plugged causing open overload or

high pressure cut-out.

2. Defective starting capacitor.
3. Defective starting relay.
4. Open motor winding.

5. No power output from compressor output terminal

on control board.

1. Clean condenser coil and replace overload if

necessary.

2. Replace start capacitor.
3. Replace relay.
4. Ohm out windings and replace compressor if

necessary.

5. Check terminal connection and replace control board

if necessary.

Unit cycles intermittently.

System status: compressor,

gearmotor, and fan motor

cycle.

1. Float reservoir running dry, sensing probe

signalling for system to shut down.

1. Check water supply to float and float operation. PC

board will have flashing WTR LED.

Low ice production.

Poor quality ice.

1. Dirty air filter or condenser coil.
2. Restricted air flow to condenser coil.
3. Mineral coated evaporator.
4. Improper exhaust air provisions.

5. Faulty expansion valve.
6. Low refrigerant charge.

7. Superheat incorrect.

8. Inefficient compressor.

1. Clean or replace filter, clean condenser.
2. Remove obstruction.
3. Clean evaporator.
4. Provide proper exhaust air provisions per Follett

installation manual.

5. Replace expansion valve.
6. Check for leaks; repair, evacuate, and weigh in correct

charge.

7. Check that TXV sensing bulb is securely clamped in

place and not damaged; check that insulated bulb

cover is in place.

8. Replace compressor.

Water leaks from bottom of

evaporator.

1. O ring seal broken.

1. Replace O ring.

Icemaker runs for short

period of time and shuts

down on torque error.

System status: 20M or 2nd

LED is lit.

1. Kink in ice transport tube.

2. Bin level control remains in closed position.
3. Ice transport tube ruptured internally.
4. Worn evaporator bearings.

5. Faulty gearmotor start relay. Icemaker torques out

within 5 seconds of start-up.

6. Torque out occurs when storage bin fills to capacity.

1. Eliminate kink and check that tube routing complies

with Follett icemaker installation manual.

2. Adjust or replace control.
3. Replace complete length of ice transport tube.
4. Inspect bearings for roughness or binding and replace

if necessary.

5. Replace gearmotor start relay.

6. Ensure that ice contacts bin thermostat before

backing ice up in transport tube. Refer to dispenser

manual for proper thermostat and ice tube mounting.

Evaporator is iced up on the

outside. No ice production.

System status: compressor,

gearmotor and fan motor

running.

1. Gearmotor running but no output rotation.

2. Float reservoir empty.

3. Air bubble in water supply line. Water

in reservoir but not in evaporator.

1. Check for broken gearmotor output shaft or damaged

gearbox.

2. Check for defective water sensor (water OK (WTR)

LED remains on even when float empty or probe

removed from water).

3. Purge air from line.

Advertising
This manual is related to the following products: