25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A

5

Electrical

115V, 60Hz, 1 phase, 14.0 amps. Connect to dedicated 20 amp circuit, fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Furnished with 7 ft (2m) power cord with a 90° NEMA hospital grade 5-20 plug.

Ambient

Maximum

Minimum

Air temp

100 F/38 C (Best performance below 80 F/27 C)

50 F/10 C

Water temp

90 F/32 C (Best performance below 70 F/21 C)

40 F/4 C

Water pressure

70 P.S.I.

10 P.S.I.

Plumbing

Connections – 25/50CI400A/W

Rough-ins – 25/50HI400A/

Dispenser drain

All – 3/4" FNPT

Air-cooled – 3/4" FNPT

Water inlet

All – 3/8" FNPT

All – 1/2" FNPT

Condenser inlet

Water-cooled – 3/8" FNPT

N/A

Condenser outlet

Water-cooled – 3/8" FNPT

N/A

Note: Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard-piped

and insulated. Maintain at least 1/4" per foot (20mm per 1m run) of slope on horizontal runs.

CAUTION

• Do not block left side air intake or right side air exhaust

Ventilation and service clearances

Air-cooled

Water-cooled

Required for ventilation

3" (77mm) each side

N/A

Suggested for service

12" (305mm) top,

6"(153mm) left side

12" (305mm) top

Uncrated weight

25/50CI400A/W (countertop)

215 lbs (98kg)

25/50HI400A (wall mount)

230 lbs (105kg)