Dispenser troubleshooting, Before calling for service, Lever model troubleshooting guide – Follett Symphony 50HI400A 23 User Manual

Page 31: Sensorsafe model troubleshooting guide, Warning

Advertising
background image

25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A

31

Dispenser troubleshooting

Before calling for service

1. Check for ice in the ice storage area.
2. Check that congealed ice is not causing a jam.
3. Check that all switches and circuit breakers are on.
4. Check that all drains are clear.

WARNING

• Disconnect power to unit before putting

hands or arms in storage area or attempting

any repair or service to equipment

Lever model troubleshooting guide

Problem

Indicators

Corrective Action

Does not dispense ice.

1. Power switch off or faulty.
2. Faulty dispense switch.
3. Wheel motor malfunction.

1. Check switch – turn on or replace if faulty.
2. Replace switch.
3. Check motor and capacitor and replace

Dispense wheel rotates continuously.

Dispense switch contacts are burned out.

Replace dispense switch.

Icemaker runs continuously.

Faulty or incorrectly positioned bin stat.

Check for proper positioning. If stat does not

open when ice is placed on capillary tube,

replace stat.

Does not dispense water.

1. Faulty water solenoid valve.
2. Faulty dispense switch.
3. Power switch off or faulty.

1. Replace water solenoid valve.
2. Replace dispense switch.
3. Check switch - turn on or replace if faulty.

SensorSAFE model troubleshooting guide

Problem

Action

SensorSAFE Board LED Status

Corrective Action

PWR

CLN

ICE/WTR

Does not dispense

ice and/or water.

Check LEDs on the

SensorSAFE control

board.

OFF

OFF

OFF

Check circuit breakers and power switch. Restore power or

replace defective switch.

ON

ON

OFF

Press clean switch on lower left side of electrical enclosure

to return board to normal operation.

Place cup under drop

zone (in front of lens)

ON

OFF

OFF

Troubleshoot appropriate lens/sensor and replace if required

(see lens/sensor troubleshooting).

ON

OFF

ON

Verify power on appropriate output terminal (WTR or WM)

on control board and replace board if required. If board tests

okay, troubleshoot appropriate dispenser component.

Dispenses ice

and/or water

continuously.

Check LEDs on

control board.

ON

OFF

ON

Troubleshoot appropriate lens/sensor and replace if required

(see lens/sensor troubleshooting).

ON

OFF

OFF

If there is power on any output terminal 9WTR or WM) on

control board, replace board.

Board guide

LEDs, when illuminated, indicate the following: PWR (board power), CLN (cleaning, no dispensing cycle), ICE (ice

dispensing activated), WTR (water dispensing activated).

Terminals: LI (incoming power, hot), L2 (neutral terminals), WTR (power terminal for water solenoid), WM (power
terminal for wheelmotor), CLN (terminals for clean cycle switch).

Lens/sensor troubleshooting

1. Turn dispenser power switch off and remove splash panel.
2. Disconnect wires from WTR and WM terminals on board.
3. Gently remove sensor/mounting block from splash panel.
4. Inspect lens and sensor. Clean if necessary.
5. Restore dispenser power and test sensor by passing hand in front of sensor.
6. If LED on board turns on, sensor is operational. Re-assemble dispenser.
7. If LED does not come on, switch sensor leads on board and retest.
8. If opposite LED comes on, replace defective board.
9. If opposite LED does not come on, replace defective sensor.

Advertising
This manual is related to the following products: