20. Turn power to icemaker OFF.
21. Disconnect transport tube from evaporator outlet

port. Rinse compression nozzle in clean water and

reinstall on evaporator outlet. Reconnect transport

tube to compression nozzle.

22. Drain any remaining sanitizing solution from

evaporator.

23. Fill reservoir almost to overflowing with clean,

120 F (49 C) water, and drain. Repeat three times.

24. Open water supply valve and replace reservoir

cover. Restore power to icemaker and ensure

compressor switch is in ON position. Make ice for

at least 15 minutes to flush any remaining solution

from system. Discard this and all ice made during

sanitizing.

25. Inspect evaporator drain pan and drain line and

remove any accumulated scale build up.

26. Replace any panels removed prior to cleaning.

Start-up following cleaning

1. Clean and sanitize ice storage area of dispenser in

accordance with instructions before making ice.

2. Turn icemaker on and begin to make ice. Icemaker

should start immediately with power and bin signal

supplied.

3. After approximately 30 minutes, test dispenser for

proper dispensing.