Caution – Furuno FR-2115/2125 User Manual

Page 11

Advertising
background image

1-3

O-ring

Radiator bracket

Waveguide

Antenna radiator

Hex bolt (M8X40), 8 pcs.
(XN20AF, XN24AF only)

Guide pin
(XN20AF,

XN24AF
only)

Hex bolt (M8X35), 8 pcs.
Flat washer
Spring washer

(XN12AF only)

Figure 1-3 Fastening the radiator to the radiator bracket

Fastening the scanner unit to the mounting platform

The scanner unit may be assembled before hoisting it to the mounting platform.
However, do not lift the scanner unit by the radiator. Always hold the unit by its
housing. When using a crane or hoist, lift the unit by the hoist rings which should
be fastened to the bolt fixing covers of the scanner housing.

130cm

CAUTION

CAUTION

DO NOT lift the antenna unit by the radiator; lift it by the
hoist rings. (Be sure to remove rings after hoisting the
antenna unit.)

Hoist
ring

NO!

1. Construct a suitable mounting platform referring to the outline drawing at the

back of the manual.

2. Drill four mounting holes of 15 mm diameter and one cable entry hole of about

50 mm diameter in the mounting platform.

3. Lay the rubber mat (supplied) on the mounting platform.

Advertising