ARP board adjustment

1. Turn the GAIN, A/C SEA and A/C RAIN controls fully counterclockwise, and

then transmit on the 12 nm range.

2. Connect a digital multimeter between TP7(+) and TP6(-) on the ARP Board.

TP7

TP6

R104 R103

Figure 4-6 ARP Board (18P9002B)

3. Adjust R104 on the ARP Board so the multimeter reads between 0.09 and 0.14

VDC.

4. Set controls and switches as below.

GAIN: fully clockwise (max.)
Interference rejector: OFF
Range: 24 nm
Echo stretch: OFF

5. Press [RADAR MENU] [0] [0] [0] [0] open the INITIAL SETTING3 menu.

6. Set the VIDEO SIG field to DIGITAL and press [ENTER].

7. Adjust R103 on the ARP Board so noise just appears on the display.

Too little noise

Proper noise

Too much noise

Figure 4-7 How to adjust noise

8. Set VIDEO SIG to ANALOG and press [ENTER].