Caution, Figure 1-5 how to mount the scanner unit – Furuno FR-2115/2125 User Manual

Page 12

Advertising
background image

1-4

4. Place the scanner unit on the rubber mat orienting the unit so the bow mark on

its base is facing the ship’s bow.

Ground
terminal

Rubber
mat

Bow mark

Figure 1-4 Scanner unit, front view

5. Fasten the scanner unit to the mounting platform with M12x60 hex bolts, nuts,

flat washers and seal washers.

6. Using hex bolt (M6x25), nut (M6) and flat washer (M6) establish the ground

system on the mounting platform as shown in Figure 1-5. The location should
be within 370 mm of the ground terminal on the scanner unit. Connect the
ground wire (RW-4747, 370 mm, supplied) between the grounding point and
ground terminal on the scanner unit. Coat the entire ground system with sili-
cone sealant (supplied).

Anticorrosive sealant

Seal washer

Rubber mat

Anticorrosive
sealant

Ground wire

Hex bolt

Hex bolt welded to
ship's superstructure

Hex nut

Hex nut

Spring washer

Spring washer

Spring washer

OR

Anticorrosive
sealant

Flat washer

Anticorrosive sealant

Ground
terminal

Ground
wire

Antenna base

Ground wire

Ground the equipment to
prevent electrical shock
and mutual interference.

CAUTION

Figure 1-5 How to mount the scanner unit

Advertising