Fabricating signal cable S03-75

1. Remove the vinyl sheath by 450 mm.

2. Slide the clamping ring, washer, rubber gas-

ket and washer onto the signal cable in that
order.

3. Unravel the outer shield to expose the cores

in the outer layer. Then, unravel the inner
shield to expose the cores in the inner layer.
Label all inner cores to aid in identification.

4. Attach EMI cores to all inner cores and all

outer cores, and tie them with cable ties, etc..

Note:There are two types of the EMI core,
thick and thin.

5. Trim each core (except coaxial wire) consid-

ering its location on the terminal board.

6. Trim the inner and outer shields leaving 500

mm each. Twist shields together and attach
crimp-on lug FV5.5-4 (blue, ø4).

7. Remove insulation of each core by about 6

mm. Fix crimp-on lug FV1.25-M3 (red, ø3) to
each core.

8. Fabricate the coaxial cable. Make the length

10 mm longer than the shield to prevent wire
strain. Attach crimp-on lug FVD1.25-3 (red,
ø3) to coaxial cable.

Figure 2-6 How to fabricate

signal cable

S03-75

VINYL SHEATH

Inner shield

6 mm

Red (

φ

3)

Crimp-on lug (FV1.25-M3)

450 mm

45 mm

Red (

φ

3)

(FVD1.25-3)

2C-2V

Cut here

50 mm

6 mm

Fold four times

Red (

φ

3)

(FVD1.25-3)

75 mm

500mm

Coax cable

Outer cores

Inner cores

= EMI cores
Outer cores : RFC-13 (thick)
Inner cores : RFC-10 (thin)

Cable tie

under

100mm

70-130mm

Clamping

ring

Washers

Rubber
gasket

Crimp-on lug
(FV5.5-5, Blue,

φ

4)

Figure 2-7 How to ground

signal cable

S03-75

Advertising