Fabricating signal cable, S03-74 – Furuno FR-2115/2125 User Manual

Page 25

Advertising
background image

2-5

Fabricating signal cable

S03-74

1. Remove the anti-corrosive sheath by 500

mm. Remove the armor and vinyl sheath
leaving 50 mm each approximately.

2. Fold back the armor and trim to suitable

length. Then, slide the washer, rubber gas-
ket, washer and clamping ring onto the
cable in that order.

3. Unravel the outer shield to expose the cores

in the outer layer. Then, unravel the inner
shield to expose the cores in the inner layer.
Label all inner cores for later identification.

4. Attach EMI cores to all inner cores and

outer cores, and tie them with cable ties,
etc..

Note: There are two types of EMI core, thick
and thin.

5. Trim each core (except coaxial core) con-

sidering its location on the terminal board.

6. Trim the inner and outer shields leaving 50

cm each. Twist shields together and attach
crimp-on lug FV5.5-4 (blue, ø4).

7. Remove insulation of each core by 6 mm

approximately. Attach crimp-on lug
FV1.25-M3 (red, ø3) to each core.

8. Fabricate the coaxial cable. Make the length

10 mm longer than the shield to prevent
wire strain. Attach crimp-on lug FVD1.25-3
(red, ø3) to coaxial cable.

Figure 2-8 How to fabricate

signal cable

S03-74

ANTICORROSIVE SHEATH

500 mm

Inner shield

50 mm

Vinyl sheath

Armor

Outer sheath

Coax cable

Crimp-on lug

Shield

45 mm

Red (

φ

3)

(FVD1.25-3)

2C-2V

Cut here

50 mm

6 mm

Fold four times

Red (

φ

3)

(FVD1.25-3)

75 mm

FV1.25-L3

FV2-4 (Blue)

Coax cable

Outer cores

Inner cores

=EMI cores
Outer cores : RFC-13 (thick)
Inner cores : RFC-10 (thin)

Cable tie

under

100mm

70-130mm

Figure 2-9 How to ground

signal cable

S03-74

Clamping

ring

Washers

Rubber
gasket

Crimp-on lug
(FV5.5-5, Blue,

φ

4)

Armor

Advertising